<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ICECAT-interface SYSTEM "https://data.icecat.biz/dtd/ICECAT-interface_response.dtd">
<!--source: Icecat.biz 2026-->
<!--Language ID: 5-->
<!--Version: v2-->
<ICECAT-interface xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="https://data.icecat.biz/xsd/ICECAT-interface_response.xsd">
 <Product Code="1" HighPic="https://images.icecat.biz/img/norm/high/474268-5983.jpg" HighPicHeight="1580" HighPicSize="127196" HighPicWidth="1580" ID="474268" LowPic="https://images.icecat.biz/img/norm/low/474268-5983.jpg" LowPicHeight="200" LowPicSize="6144" LowPicWidth="200" Name="DGS-3048 - Managed Layer 2 Gigabit Switch" IntName="DGS-3048 - Managed Layer 2 Gigabit Switch" LocalName="" Pic500x500="https://images.icecat.biz/img/norm/medium/474268-5983.jpg" Pic500x500Height="500" Pic500x500Size="27777" Pic500x500Width="500" Prod_id="DGS-3048" Quality="ICECAT" ReleaseDate="" ThumbPic="https://images.icecat.biz/thumbs/474268.jpg" ThumbPicSize="1663" Title="D-Link DGS-3048 - Managed Layer 2 Gigabit Switch" GeneratedIntTitle="D-Link DGS-3048 - Managed Layer 2 Gigabit Switch" GeneratedLocalTitle="D-Link DGS-3048 - Managed Layer 2 Gigabit Switch" BrandLocalTitle="">
  <CategoryFeatureGroup ID="31974" No="0">
   <FeatureGroup ID="0">
    <Name ID="455293" langid="5" Value="Dettagli tecnici"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="763" No="195">
   <FeatureGroup ID="12">
    <Name ID="455276" langid="5" Value="Connettività"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1144" No="135">
   <FeatureGroup ID="14">
    <Name ID="455278" langid="5" Value="Dimensioni e peso"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1142" No="150">
   <FeatureGroup ID="27">
    <Name ID="455290" langid="5" Value="Gestione energetica"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1143" No="140">
   <FeatureGroup ID="28">
    <Name ID="455291" langid="5" Value="Condizioni ambientali"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2987" No="165">
   <FeatureGroup ID="34">
    <Name ID="455297" langid="5" Value="Protocolli"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1141" No="190">
   <FeatureGroup ID="35">
    <Name ID="2576354" langid="5" Value="Collegamento in rete"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2484" No="180">
   <FeatureGroup ID="62">
    <Name ID="455322" langid="5" Value="Trasmissione dati"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2483" No="125">
   <FeatureGroup ID="67">
    <Name ID="2576357" langid="5" Value="Dati su imballaggio"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2482" No="175">
   <FeatureGroup ID="75">
    <Name ID="455335" langid="5" Value="Sicurezza"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="41469" No="0">
   <FeatureGroup ID="76">
    <Name ID="455336" langid="5" Value="Certificati di sicurezza"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2944" No="200">
   <FeatureGroup ID="93">
    <Name ID="455351" langid="5" Value="Caratteristiche di gestione"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="49104" No="130">
   <FeatureGroup ID="116">
    <Name ID="455373" langid="5" Value="Contenuto dell'imballo"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="5713" No="185">
   <FeatureGroup ID="137">
    <Name ID="2576355" langid="5" Value="Fibra ottica"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="53530" No="0">
   <FeatureGroup ID="143">
    <Name ID="618816" langid="5" Value="Batteria"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8343" No="144">
   <FeatureGroup ID="146">
    <Name ID="624350" langid="5" Value="Altre caratteristiche"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10881" No="160">
   <FeatureGroup ID="148">
    <Name ID="630461" langid="5" Value="Design"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="9999" No="145">
   <FeatureGroup ID="174">
    <Name ID="1318110" langid="5" Value="Power over Ethernet (PoE)"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10882" No="155">
   <FeatureGroup ID="184">
    <Name ID="1318115" langid="5" Value="Prestazione"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="70398" No="0">
   <FeatureGroup ID="185">
    <Name ID="1318116" langid="5" Value="Caratteristiche"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="24990" No="-100">
   <FeatureGroup ID="198">
    <Name ID="1840367" langid="5" Value="Dati logistici"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="60022" No="0">
   <FeatureGroup ID="232">
    <Name ID="3568556" langid="5" Value="Composizione del prodotto"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="27921" No="170">
   <FeatureGroup ID="252">
    <Name ID="4400738" langid="5" Value="Funzioni Multicast"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="76178" No="120">
   <FeatureGroup ID="279">
    <Name ID="7392242" langid="5" Value="Sostenibilità"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="77984" No="0">
   <FeatureGroup ID="305">
    <Name ID="8856881" langid="5" Value="Impronta di carbonio"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <Category ID="258">
   <Name ID="3845728" langid="5" Value="Switch di rete"/>
  </Category>
  <EANCode/>
  <ReleaseDate/>
  <EndOfLifeDate/>
  <ReasonsToBuy/>
  <BulletPoints/>
  <GeneratedBulletPoints>
   <GeneratedBulletPoint Value="RMON, SNMP v1/2/3, TFTP, STP, RSTP, MSTP, IGMP, BootP, DHCP" langid="5" No="1"/>
   <GeneratedBulletPoint Value="Quantità di porte RJ-45: 48" langid="5" No="2"/>
   <GeneratedBulletPoint Value="1000Base-T, 100Base-TX, 10Base-T" langid="5" No="3"/>
   <GeneratedBulletPoint Value="Dimensioni tavola MAC: 16000 voci Capacità di commutazione: 96 Gbit/s" langid="5" No="4"/>
  </GeneratedBulletPoints>
  <ProductBundled/>
  <ProductDescription/>
  <ProductFeature Localized="0" ID="14361904" Local_ID="0" Value="48" CategoryFeature_ID="86090" CategoryFeatureGroup_ID="763" No="10100100" Optional="0" Presentation_Value="48" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="48">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="13503">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1098932" langid="5" Value="Quantità di porte RJ-45"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361946" Local_ID="0" Value="IEEE 802.1d,IEEE 802.1p,IEEE 802.1q,IEEE 802.1w,IEEE 802.3,IEEE 802.3ab,IEEE 802.3ad,IEEE 802.3u,IEEE 802.3x,IEEE 802.3z" CategoryFeature_ID="45644" CategoryFeatureGroup_ID="1141" No="100999" Optional="0" Presentation_Value="IEEE 802.1d, IEEE 802.1p, IEEE 802.1q, IEEE 802.1w, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="IEEE 802.1d, IEEE 802.1p, IEEE 802.1q, IEEE 802.1w, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1802">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="461454" langid="5" Value="Standard di rete"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361911" Local_ID="0" Value="1000Base-T,100Base-TX,10Base-T" CategoryFeature_ID="2027" CategoryFeatureGroup_ID="1141" No="100099" Optional="0" Presentation_Value="1000Base-T, 100Base-TX, 10Base-T" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1000Base-T, 100Base-TX, 10Base-T">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7659">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1052767" langid="5" Value="Tecnologia Ethernet su cavi in rame"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361934" Local_ID="0" Value="Y" CategoryFeature_ID="2042" CategoryFeatureGroup_ID="1141" No="100002" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="536">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="461204" langid="5" Value="Full duplex"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361951" Local_ID="0" Value="Y" CategoryFeature_ID="16314" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2756">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="459889" langid="5" Value="Supporto controllo flusso"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361912" Local_ID="0" Value="16000" CategoryFeature_ID="2026" CategoryFeatureGroup_ID="2484" No="10100086" Optional="0" Presentation_Value="16000 voci" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="16000">
    <Measure ID="56">
     <Signs>
      <Sign ID="18763" langid="5"><![CDATA[voci]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="566">
    <Measure ID="56" Sign="">
     <Signs>
      <Sign ID="18763" langid="5"><![CDATA[voci]]></Sign>
     </Signs>
    </Measure>
    <Name ID="459421" langid="5" Value="Dimensioni tavola MAC"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361915" Local_ID="0" Value="96" CategoryFeature_ID="11205" CategoryFeatureGroup_ID="2484" No="100090" Optional="0" Presentation_Value="96 Gbit/s" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="96">
    <Measure ID="68">
     <Signs>
      <Sign ID="6777" langid="5"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1801">
    <Measure ID="68" Sign="">
     <Signs>
      <Sign ID="6777" langid="5"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="459885" langid="5" Value="Capacità di commutazione"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361905" Local_ID="0" Value="10/100/1000 Mbps" CategoryFeature_ID="2029" CategoryFeatureGroup_ID="2484" No="100999" Optional="1" Presentation_Value="10/100/1000 Mbps" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10/100/1000 Mbps">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="606">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="456596" langid="5" Value="Velocità di trasferimento dati supportate"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361903" Local_ID="0" Value="1" CategoryFeature_ID="8769" CategoryFeatureGroup_ID="2484" No="100022" Optional="1" Presentation_Value="1 Gbit/s" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="68">
     <Signs>
      <Sign ID="6777" langid="5"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="3188">
    <Measure ID="68" Sign="">
     <Signs>
      <Sign ID="6777" langid="5"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="456226" langid="5" Value="Massima velocità di trasferimento"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361932" Local_ID="0" Value="Y" CategoryFeature_ID="18564" CategoryFeatureGroup_ID="2482" No="100000" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3122">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="459896" langid="5" Value="Filtri MAC address"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361907" Local_ID="0" Value="RMON, SNMP v1/2/3, TFTP, STP, RSTP, MSTP, IGMP, BootP, DHCP" CategoryFeature_ID="2036" CategoryFeatureGroup_ID="2987" No="119334" Optional="0" Presentation_Value="RMON, SNMP v1/2/3, TFTP, STP, RSTP, MSTP, IGMP, BootP, DHCP" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="RMON, SNMP v1/2/3, TFTP, STP, RSTP, MSTP, IGMP, BootP, DHCP">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="502">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="459401" langid="5" Value="Protocolli di gestione"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361923" Local_ID="0" Value="8" CategoryFeature_ID="14689" CategoryFeatureGroup_ID="10882" No="100001" Optional="0" Presentation_Value="8 MB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8">
    <Measure ID="19">
     <Signs>
      <Sign ID="6732" langid="5"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="538">
    <Measure ID="19" Sign="">
     <Signs>
      <Sign ID="6732" langid="5"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="458030" langid="5" Value="Memoria flash"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361908" Local_ID="0" Value="CLI/Console, Web-based HTTP, Telnet" CategoryFeature_ID="2035" CategoryFeatureGroup_ID="8343" No="119333" Optional="1" Presentation_Value="CLI/Console, Web-based HTTP, Telnet" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="CLI/Console, Web-based HTTP, Telnet">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="665">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="461206" langid="5" Value="Piattaforma di gestione"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361928" Local_ID="0" Value="440 x 309 x 44" CategoryFeature_ID="5038" CategoryFeatureGroup_ID="8343" No="100050" Optional="1" Presentation_Value="440 x 309 x 44 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="440 x 309 x 44">
    <Measure ID="24">
     <Signs>
      <Sign ID="6737" langid="5"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="49">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="6737" langid="5"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="459980" langid="5" Value="Dimensioni (LxPxA)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361958" Local_ID="0" Value="100-240V AC, 50/60 Hz" CategoryFeature_ID="8356" CategoryFeatureGroup_ID="8343" No="100000" Optional="1" Presentation_Value="100-240V AC, 50/60 Hz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="100-240V AC, 50/60 Hz">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="780">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="460050" langid="5" Value="Alimentazione"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361963" Local_ID="0" Value="Port security" CategoryFeature_ID="14690" CategoryFeatureGroup_ID="8343" No="100000" Optional="1" Presentation_Value="Port security" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Port security">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="248">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="459994" langid="5" Value="Caratteristiche sicurezza"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361964" Local_ID="0" Value="802.1x, RADIUS/TACACS+" CategoryFeature_ID="17384" CategoryFeatureGroup_ID="8343" No="100000" Optional="1" Presentation_Value="802.1x, RADIUS/TACACS+" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="802.1x, RADIUS/TACACS+">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1557">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="459891" langid="5" Value="Metodo di autenticazione"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361971" Local_ID="0" Value="0 - 40" CategoryFeature_ID="7827" CategoryFeatureGroup_ID="1143" No="100040" Optional="0" Presentation_Value="0 - 40 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0 - 40">
    <Measure ID="65">
     <Signs>
      <Sign ID="6774" langid="5"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1112">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="6774" langid="5"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="460215" langid="5" Value="Intervallo temperatura di funzionamento"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361970" Local_ID="0" Value="10 - 70" CategoryFeature_ID="7830" CategoryFeatureGroup_ID="1143" No="100039" Optional="0" Presentation_Value="10 - 70 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10 - 70">
    <Measure ID="65">
     <Signs>
      <Sign ID="6774" langid="5"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="757">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="6774" langid="5"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="460047" langid="5" Value="Intervallo di temperatura"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361969" Local_ID="0" Value="10 - 90" CategoryFeature_ID="7825" CategoryFeatureGroup_ID="1143" No="100035" Optional="0" Presentation_Value="10 - 90%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10 - 90">
    <Measure ID="64">
     <Signs>
      <Sign ID="6773" langid="5"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="703">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="6773" langid="5"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="460038" langid="5" Value="Range di umidità di funzionamento"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361972" Local_ID="0" Value="0 - 95" CategoryFeature_ID="12190" CategoryFeatureGroup_ID="1143" No="100034" Optional="0" Presentation_Value="0 - 95%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0 - 95">
    <Measure ID="64">
     <Signs>
      <Sign ID="6773" langid="5"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1383">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="6773" langid="5"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="460275" langid="5" Value="Umidità"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361918" Local_ID="0" Value="48x Gigabit Ethernet&#10;4x Combo SFP" CategoryFeature_ID="6908" CategoryFeatureGroup_ID="8343" No="0" Optional="1" Presentation_Value="48x Gigabit Ethernet&#10;4x Combo SFP" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="48x Gigabit Ethernet&#10;4x Combo SFP">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="470">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="460014" langid="5" Value="Porte I/O"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14361980" Local_ID="0" Value="CE Mark, FCC Class A, VCCI Class I, C-Tick" CategoryFeature_ID="11201" CategoryFeatureGroup_ID="8343" No="0" Optional="1" Presentation_Value="CE Mark, FCC Class A, VCCI Class I, C-Tick" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="CE Mark, FCC Class A, VCCI Class I, C-Tick">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="803">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="456617" langid="5" Value="Emissioni elettromagnetiche"/>
   </Feature>
  </ProductFeature>
  <ProductGallery>
   <ProductPicture IsMain="Y" LowPic="https://images.icecat.biz/img/norm/low/474268-5983.jpg" LowPicHeight="200" LowPicWidth="200" LowSize="6144" No="1" Original="https://images.icecat.biz/img/norm/high/474268-5983.jpg" OriginalSize="123792" Pic="https://images.icecat.biz/img/norm/high/474268-5983.jpg" Pic500x500="https://images.icecat.biz/img/norm/medium/474268-5983.jpg" Pic500x500Height="500" Pic500x500Size="27777" Pic500x500Width="500" PicHeight="1580" PicWidth="1580" ProductPicture_ID="13403182" Size="127196" ThumbPic="https://images.icecat.biz/thumbs/474268.jpg" ThumbSize="1663" Type="ProductImage" UpdatedDate="2017-03-29 11:48:31"/>
  </ProductGallery>
  <ProductMultimediaObject>
   <MultimediaObject ContentType="application/pdf" Date="2018-01-04 02:14:32" Description="Generated PDF" KeepAsURL="0" MultimediaObject_ID="0" Type="leaflet" UUID="00000000-0000-0000-0000-000000000000" langid="5" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="0" URL="https://icecat.biz/rest/product-pdf?productId=474268&amp;lang=it" Width="0"/>
  </ProductMultimediaObject>
  <ProductRelated ID="2402545" Category_ID="963" Preferred="0">
   <Product ID="102453" Prod_id="DPS-500" ThumbPic="" Name="DPS-500">
    <Supplier ID="63" Name="D-Link"/>
   </Product>
   <ProductRelatedLocales>
    <ProductRelatedLocale ID="0" langid="0" Preferred="0" StartDate="" EndDate=""/>
   </ProductRelatedLocales>
  </ProductRelated>
  <ProductRelated ID="2402546" Category_ID="238" Preferred="0">
   <Product ID="85330" Prod_id="DPS-900" ThumbPic="" Name="DPS-900">
    <Supplier ID="63" Name="D-Link"/>
   </Product>
   <ProductRelatedLocales>
    <ProductRelatedLocale ID="0" langid="0" Preferred="0" StartDate="" EndDate=""/>
   </ProductRelatedLocales>
  </ProductRelated>
  <ProductRelated ID="2402548" Category_ID="1504" Preferred="0">
   <Product ID="43810" Prod_id="DS-510P" ThumbPic="" Name="D-View SNMP Network Management System">
    <Supplier ID="63" Name="D-Link"/>
   </Product>
   <ProductRelatedLocales>
    <ProductRelatedLocale ID="0" langid="0" Preferred="0" StartDate="" EndDate=""/>
   </ProductRelatedLocales>
  </ProductRelated>
  <ProductRelated ID="2402547" Category_ID="1504" Preferred="0">
   <Product ID="43809" Prod_id="DS-510S" ThumbPic="" Name="D-View SNMP Network Management System">
    <Supplier ID="63" Name="D-Link"/>
   </Product>
   <ProductRelatedLocales>
    <ProductRelatedLocale ID="0" langid="0" Preferred="0" StartDate="" EndDate=""/>
   </ProductRelatedLocales>
  </ProductRelated>
  <ProductRelated ID="2402544" Category_ID="1869" Preferred="0">
   <Product ID="37398" Prod_id="DEM-311GT" ThumbPic="" Name="DEM-311GT">
    <Supplier ID="63" Name="D-Link"/>
   </Product>
   <ProductRelatedLocales>
    <ProductRelatedLocale ID="0" langid="0" Preferred="0" StartDate="" EndDate=""/>
   </ProductRelatedLocales>
  </ProductRelated>
  <ProductRelated ID="2402543" Category_ID="1869" Preferred="0">
   <Product ID="37397" Prod_id="DEM-310GT" ThumbPic="" Name="1000Base-LX Mini Gigabit Interface Converter">
    <Supplier ID="63" Name="D-Link"/>
   </Product>
   <ProductRelatedLocales>
    <ProductRelatedLocale ID="0" langid="0" Preferred="0" StartDate="" EndDate=""/>
   </ProductRelatedLocales>
  </ProductRelated>
  <SummaryDescription>
   <ShortSummaryDescription langid="5">D-Link DGS-3048 - Managed Layer 2 Gigabit Switch, Full duplex</ShortSummaryDescription>
   <LongSummaryDescription langid="5">D-Link DGS-3048 - Managed Layer 2 Gigabit Switch. Quantità di porte RJ-45: 48. Full duplex. Dimensioni tavola MAC: 16000 voci, Capacità di commutazione: 96 Gbit/s. Standard di rete: IEEE 802.1d, IEEE 802.1p, IEEE 802.1q, IEEE 802.1w, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE...</LongSummaryDescription>
  </SummaryDescription>
  <Supplier ID="63" Name="D-Link"/>
  <CatalogObjectCloud>
   <ProductPage QRCodeURL="https://qr.icecat.biz/coc/ac23c357-0f85-4baa-9706-d8e347ce5c1f" URL="https://coc.icecat.biz/ac23c357-0f85-4baa-9706-d8e347ce5c1f"/>
  </CatalogObjectCloud>
 </Product>
</ICECAT-interface>
